Features
Die-cast aluminum housing reduces weight and noise while providing superior heat dissipation
6 or 8-bolt housing pattern for simplified installation across popular transmission applications
Constant mesh input gear isolates the transmission from engagement errors during PTO shifts
Electric or hydraulic shift option eliminates the need for shift cables
Rotatable hydraulic flanges maximize pump clearance for flexible mounting
Extra-large shift cover opening allows easy access to check backlash
Tech Specs
Additional Information
| PTO TORQUE & HORSEPOWER RATINGS | ||||||
|---|---|---|---|---|---|---|
| Speed Ratio | Intermittent HP @ 1000 RPM | Intermittent Torque (lb-ft) | Continuous Torque (lb-ft) | Intermittent (kW) @ 1000 RPM | Intermittent Torque (Nm) | Continuous Torque (Nm) |
| 04 | 54 | 285 | 200 | (40) | (386) | (270) |
| 05 | 51 | 270 | 189 | (38) | (366) | (256) |
| 06 | 47 | 245 | 172 | (35) | (332) | (232) |
| 07 | 44 | 230 | 161 | (33) | (312) | (218) |
| 08 | 44 | 230 | 161 | (33) | (312) | (218) |
| 09 | 39 | 205 | 144 | (29) | (278) | (195) |
| 12H | 40 | 210 | 147 | (30) | (284) | (199) |
| 13H | 40 | 210 | 147 | (30) | (284) | (199) |
| 15H | 37 | 195 | 137 | (28) | (264) | (185) |
| 18H | 33 | 175 | 123 | (25) | (237) | (166) |